The BallastMaster ultraV provides efficient treatment of ballast water by means of filtration and UV-C radiation and is available with capacities of 250 or 500 cubic meters per hour.

The BallastMaster ultraV developed by GEA Westfalia Separator Group for treating ballast water has been awarded the "Alternate Management System" (AMS) certificate. The approval was awarded by the United States Coast Guard (USCG) on November 11, 2013 and is considered to be the standard for the international recognition and selection of suppliers of ballast water processing installations. The AMS certificate is considered by the USCG to be a transitional measure until the type approval process has been formally implemented in American legislation. The cooperation of GEA Westfalia Separator Group with the USCG for gaining type approval for the BallastMaster ultraV system guarantees the important market access in the long term.

Independently of existing IMO regulations, the USA implemented its own regulations for the treatment of ballast water via the "Vessel General Permit" (VGP) of the USCG in 2012. The regulations of the USCG are applicable for all new vessels whose keels were laid down after 1 December 2013. Existing vessels with keels laid down before 1 December 2013 and with a ballast water capacity of 1,500 to 5,000 m³ must comply with the US regulations after their first scheduled docking from 1 January 2014. For existing vessels with a ballast water capacity of less than 1,500 m³ and more than 5,000 m³, this is applicable after the first docking after January 1, 2016.

Pre-cleaning by mechanical filtration
The ballast water management system BallastMaster ultraV is an extremely efficient mechanical and physical system solution for treating ballast water, including ballast water with high concentrations of organisms and sediment particles. The two-stage system works with mechanical pre-filtration and subsequent disinfection of the ballast water by means of UVC radiation without using and/or generating chemicals. In the first stage, an upstream mechanical filtration system removes all organisms and sedimentary particles larger than 20 microns. This reliably prevents sedimentary deposits from accumulating in the ballast water tanks, as well as guaranteeing in the second stage an optimum result for ballast water disinfecting. The filter modules are cleaned automatically by vacuum extraction (self-cleaning).

Disinfecting by means of UV-C radiation
In the second stage, the pre-filtered ballast water is disinfected by UV-C radiation. The monochromatic UV-C radiation (254 nm) effectively destroys organisms such as bacteria or phytoplankton. A microcavitation technology effected by ultrasonic ensures that the biofilms and inorganic deposits on the cladding of the UV-C tubes are cleaned off extremely efficiently and permanently.

Reliable disinfection according to IMO and USCG standards
The combination of short-wave UV-C radiation and ultrasound cleaning of the radiation units ensures effective disinfection of constant quality in line with the regulations, and thus ensures that all port controls are passed without any problems. Following successful type approval in accordance with IMO in the year 2011, the BallastMaster ultraV with the AMS certificate is now also approved without any restriction for U.S. waters.

gea.com
 

  • The low-pressure UV lamps (LPUV) in the BallastMaster ultraV emit monochrome light, specifically utilizing the effect of disabling unwanted microorganisms

    The low-pressure UV lamps (LPUV) in the BallastMaster ultraV emit monochrome light, specifically utilizing the effect of disabling unwanted microorganisms

Maritime Today


The Maritime Industry's original and most viewed E-News Service

Maritime Reporter January 2016 Digital Edition
FREE Maritime Reporter Subscription
Latest Maritime News    rss feeds

News

IOCs Stress on OSV Fuel Management Performance

Growing insistence by international oil companies (IOCs) that oilfield contract vessels (OSVs) are fitted with fuel monitoring systems has prompted an upsurge in

CMA CGM Increases Port Calls and TEU Capacity

French container line CMA CGM has announced imminent changes to its PCRF line service which links Northern Europe with the French West Indies, by adding two new

China's LNG Demand Falls

China's import of  liquefied natural gas (LNG) fell 1.1% in 2015, marking the first year-on-year decline since imports began in 2006, according to a report by

Marine Equipment

Furuno Establishes China Subsidiary

FURUNO ELECTRIC CO., LTD. announced that its new subsidiary in Hong Kong has been established and has commenced business operation on February 1, 2016.   The new subsidiary, FURUNO CHINA CO.

Novoship to Install Ecochlor BWTS on 4 Tankers

SCF Novoship Technical Management has selected the Ecochlor Ballast Water Treatment System (BWTS) to be retrofitted on three Aframax Oil Tankers and one Product Carrier.

Seaspan Venture: Like for Like

“We don’t usually remove the heads at mid-life on the Cummins engines,” Randy Beckler, Shore Engineer for Seaspan Marine, explained in reference to the 2003 launched

Coast Guard

Attempts to Move Containership CSCL Indian Ocean Aground in Elbe Successful

The last five days stuck in Elbschlick 400-meter (1,312 feet) CSCL Indian Ocean, the 19,000 teu vessel aground on the river Elbe, owned by China Shipping Group Co.

US Coast Guard Approves Official Electronic Charts

The U.S. Coast Guard published guidance that allows mariners to use electronic charts and publications instead of paper charts, maps and publications.   Issued February 5,

Containership Detained in Tacoma for Safety Violations

The 685-foot Liberian-flagged containership Westwood Robson is being held in port after significant safety violations were discovered by Port State Control officers from U.

Ballast Water Treatment

Novoship to Install Ecochlor BWTS on 4 Tankers

SCF Novoship Technical Management has selected the Ecochlor Ballast Water Treatment System (BWTS) to be retrofitted on three Aframax Oil Tankers and one Product Carrier.

New Offshore Vessel to be Fitted with Cathelco BWTS

Cathelco is supplying a ballast water treatment (BWT) system for a new offshore vessel built by Eastern Shipbuilding Group Inc., for Harvey Gulf International Marine, LLC.

Optimarin Breaks into the Fishing Market

Ballast water treatment (BWT) specialist Optimarin has landed its first ever contract in the fishing segment. The Norwegian firm will now supply its soon to be

 
 
Maritime Security Naval Architecture Navigation Offshore Oil Pipelines Port Authority Salvage Ship Electronics Ship Simulators Winch
rss | archive | history | articles | privacy | contributors | top maritime news | about us | copyright | maritime magazines
maritime security news | shipbuilding news | maritime industry | shipping news | maritime reporting | workboats news | ship design | maritime business

Time taken: 0.1194 sec (8 req/sec)