CHALWYN Tri-Certified Flameproof Alternators

Maritime Activity Reports, Inc.

October 14, 2014

Image: Chalwyn

Image: Chalwyn

Standard automotive type alternators are a continuous potential source of ignition when operated in hazardous atmospheres where combustible concentrations of gas, vapor or dusts may exist.

Chalwyn said its flameproof alternators are ATEX and IECEx certified for hazardous Zones 1 or 2, NEC 500 Division 2 and NEC 505 Zone 2. According to the manufacturer, this revised international ‘tri-certified’ upgrade is a benefit for companies who move their machinery between U.S., Europe and other defined international zones.

ASX-200 Series

The ASX-200 Series of 12 volt Flameproof Alternators are battery excited and designed to be a direct replacement for non-flameproof alternators used on diesel engines. Some adjustments to mounting brackets and belt tensioning link may be necessary. The alternator rear cover can be rotated to provide several possible cable entry positions for convenience in wiring connections.

The ASX-200 Series is suitable for a local ambient temperature range between -30°C and +55°C and maximum output demand should not exceed 50 amps.

ASX-300 Series
Similar to the ASX-200 Series, the 24 volt range of ASX-300 Series Flameproof Alternators have many of the same characteristics with the differences as follows: Available as either Externally-Excited ASX-300 or Self-Exciting ASX-310 models that do not require a battery or external power source. The maximum output demand should not exceed 25 amps.

Both ASX-200 and ASX-300 are available with side and rear cable entry options. Chalwyn offer a wide range of optional pulleys of different belt sections and diameters to allow operation on both fixed speed and variable speed engine applications.